Demore Exterior Solutions delivers commercial-grade exterior contracting in Leroy Township for property managers, business owners, and developers. We are fully licensed under Ohio's commercial contractor statutes, OSHA-compliant, and intimately familiar with Leroy Township's local building department requirements and the Ohio Building Code.
OSHA Compliant
Written Fall Protection Plans
OBC / IECC Certified
Ohio Building Code Expert
Licensed & Insured
Commercial Contractor
Code + Energy
COMcheck Compliant
We don't just meet commercial code — we engineer to exceed it.
Permitting Authority
Local Building Department — Commercial Plan Review & Permit Required
Ohio Building Code (OBC) & Energy Code
Ohio Building Code (OBC) 2023 edition governs all commercial construction. IECC 2021 energy code applies to commercial envelope work. Ohio Fire Code (OFC) enforced on applicable occupancies.
Key Commercial Requirements We Meet & Exceed
Ohio commercial contractor license required — we are fully licensed
Wind uplift design per ASCE 7-22 required for roofing system approval
OSHA 1926 Subpart R fall protection plan mandatory on all commercial roofing
Special inspections per OBC Chapter 1705 on qualifying projects
Energy code compliance documentation (COMcheck) required for envelope work over 50%
ADA and Ohio accessibility code compliance maintained on all accessible areas
Our Standard of Excellence
Demore Exterior Solutions maintains written OSHA safety plans on every commercial site, submits complete permit packages with wind uplift calculations and energy compliance documentation, and coordinates all required third-party special inspections. We don't cut corners — we exceed the code, protect your investment, and deliver a warranty-backed commercial installation every time.
Governing Code
Residential: Ohio Residential Code (ORC)
Commercial: Ohio Building Code (OBC) + IBC
Energy Code
Residential: IECC 2021 Residential
Commercial: IECC 2021 Commercial (stricter R-values)
Wind Design
Residential: IRC prescriptive tables
Commercial: ASCE 7-22 engineered calculations
Fire Rating
Residential: Class A shingles
Commercial: FM/UL listed assemblies required
OSHA Standard
Residential: 1926.501(b)(13) residential
Commercial: 1926.502 full commercial standard
Inspections
Residential: Standard building inspection
Commercial: Special inspections per OBC Ch. 1705
TPO, EPDM, Modified Bitumen, Metal & Built-Up — fully permitted and OBC compliant.
From small retail strip centers to multi-unit apartment complexes, Demore Exterior Solutions handles commercial roofing in Leroy Township with the expertise, licensing, and code knowledge that commercial projects demand. Every installation is engineered for Northeast Ohio's demanding climate — heavy snow loads, lake-effect ice, and high-wind events.
Commercial Site Assessment & Moisture Survey
We conduct a thorough commercial roof assessment including infrared or nuclear moisture surveys to detect trapped moisture in existing insulation — critical before any re-roofing decision.
Engineering Review & System Selection
We evaluate building occupancy, structural capacity, wind zone, drainage, and energy code requirements to specify the correct roofing system — TPO, EPDM, modified bitumen, metal, or built-up.
Commercial Plan Submittal & Permitting
Full commercial permit application submitted with wind uplift calculations, material data sheets, and energy compliance documentation (COMcheck) where required.
Existing System Removal & Decking Inspection
Existing roofing removed per local ordinance (one-layer maximum often required). Structural decking inspected; deteriorated sections replaced and documented.
Vapor Retarder Installation
Where required by OBC 1408 and climate zone, vapor retarder installed before insulation to control moisture migration in the roofing assembly.
Insulation Installation (R-Value Compliance)
Polyisocyanurate or other code-approved insulation installed to achieve required R-value per IECC 2021 commercial energy code — minimum R-25 continuous in Climate Zone 5 (Northeast Ohio).
Membrane or Surface Installation
Primary roofing membrane (TPO, EPDM, mod-bit) or surface (standing seam metal, built-up) installed per manufacturer's FM/UL-listed assembly specifications.
Flashing, Penetrations & Edge Metal
All penetrations, curbs, HVAC equipment, drains, and perimeter edge metal flashed and secured per OBC 1503 and manufacturer specifications.
Drainage Verification
All drains, scuppers, and overflow drains confirmed to meet OBC 1503.4 requirements. Drainage calculations verified for code compliance.
Fall Protection Compliance & OSHA Closeout
Written OSHA 1926.502 fall protection plan maintained throughout. Site cleared, all penetrations sealed, inspections coordinated with AHJ (Authority Having Jurisdiction).
Special Inspections & Final Signoff
Third-party special inspections coordinated where required per OBC Chapter 1705. Final building department inspection obtained. Warranty documentation provided.
TPO (Thermoplastic Polyolefin)
Energy Star rated white membrane — excellent for flat roofs. Fully adhered, mechanically fastened, or ballasted per wind zone.
EPDM (Rubber Membrane)
Industry-proven 40+ year lifespan. Excellent temperature flexibility for Ohio freeze-thaw cycles.
Modified Bitumen
Asphalt-based with polymer modification. Ideal for low-slope applications with rooftop traffic.
Standing Seam Metal
50+ year lifespan. Concealed fastener system eliminates penetration points. Class A fire rated.
Built-Up Roofing (BUR)
Multi-ply redundancy for maximum protection on demanding occupancies.
Metal panel, fiber cement, and composite cladding — fire-rated, energy-code compliant.
Commercial siding in Leroy Township must meet fire rating, energy code, and moisture management requirements far more stringent than residential standards. Demore Exterior Solutions brings full OBC knowledge and commercial installation experience to every project.
Commercial Exterior Assessment
Full building envelope assessment identifying moisture intrusion, failed cladding, code deficiencies, and energy performance gaps. Occupancy type and fire rating requirements determined.
Fire Rating & Occupancy Review
Exterior wall assembly fire rating requirements per OBC Table 602 verified. IBC Section 1403 weather protection provisions reviewed for the specific occupancy and construction type.
Commercial Permit Submittal
Permit application submitted with product specifications, fire test data, wall assembly details, and energy compliance documentation as required by the local AHJ.
Existing Cladding Removal
Existing siding removed; sheathing and structure inspected for moisture damage, decay, and code deficiencies. All hazardous material protocols followed (asbestos, lead paint surveys performed where applicable).
Water-Resistive Barrier & Drainage Plane
Commercial-grade WRB installed per OBC 1403.2. Drainage plane and weep details installed to direct any incidental moisture to the exterior — critical for long-term performance.
Continuous Insulation (ci) Installation
Exterior continuous insulation installed where required by IECC 2021 commercial energy code for Climate Zone 5 — typically minimum R-7.5 ci for metal framing.
Cladding Installation
Commercial siding product (fiber cement, metal panel, composite, or engineered wood) installed per manufacturer specs and applicable OBC requirements for attachment, spacing, and clearances.
Sealant & Flashing Details
All penetrations, transitions, and terminations sealed with commercial-grade sealant per ASTM C920 standards. Kick-out, head, and window flashings installed and inspected.
Final Inspection & Closeout
Building department final inspection coordinated. Site cleaned, all documentation provided including product warranties, installation records, and energy compliance forms.
Fiber Cement Panel
Class A fire rated, impact resistant, low maintenance. Accepts field painting. Ideal for commercial and multi-family.
Metal Panel Cladding
Aluminum or steel panel systems with factory finishes. Fire rated, extremely durable, modern aesthetic.
Engineered Wood Siding
ESR-certified engineered wood with factory primer. Excellent R-value with continuous insulation.
Composite & Phenolic Panel
High-end commercial appearance with superior weather resistance and minimal maintenance.
Engineered drainage systems sized to OBC 1503.4 — protecting your building envelope and foundation.
Commercial drainage systems in Leroy Township must handle significantly higher water volumes than residential, with overflow protection and stormwater compliance requirements that residential gutters don't face. Our commercial gutter installations are engineered, not guessed.
Drainage Load Calculation
Roof area, pitch, and local rainfall intensity data used to calculate required gutter and downspout sizing per OBC 1503.4 and ASPE Plumbing Engineering Design Handbook.
Overflow Protection Design
Overflow drains or scuppers sized and positioned per OBC 1503.4.1 to prevent structural overload in the event of primary drain blockage — critical for flat and low-slope commercial roofs.
Commercial Permitting
Permit pulled where required for commercial gutter and drainage systems. Drainage calculations submitted with application where required by local AHJ.
Existing System Removal
Old gutters, downspouts, and failed drainage components removed. Fascia and structural attachment points inspected and repaired as needed.
Commercial Gutter Fabrication
Seamless gutters fabricated on-site in commercial gauge aluminum (0.032" or heavier) or galvanized steel for high-load applications. Custom profiles available for retrofit applications.
Heavy-Duty Hanger Installation
Commercial-grade hidden hangers installed at 16" OC (exceeding the 24" residential standard) with stainless or galvanized fasteners to handle Northeast Ohio ice and snow loads.
Downspout Sizing & Routing
Downspouts sized per rainfall intensity calculations. Routing planned to avoid pedestrian areas and comply with local stormwater ordinances. Splash blocks or underground connections installed.
Heat Tape Provisions (Where Specified)
Conduit and attachment provisions for heat tape/de-icing cable installed where specified — common in Northeast Ohio commercial applications to prevent ice dam damage on low-slope edges.
Load Test & Final Inspection
System tested with full water flow. All connections verified watertight. Final walkthrough with building owner/manager completed.
Seamless Aluminum (0.032"–0.040")
Heavy commercial gauge aluminum — resists deformation under ice and snow loads common in Northeast Ohio.
Galvanized Steel
Maximum strength for high-volume or high-traffic commercial applications.
Copper Gutters
Architectural-grade for historic or high-end commercial properties. 100+ year lifespan.
Box Gutters
Built-in box gutter systems for commercial and historic structures with enclosed drainage.
We work with a wide range of commercial property types throughout Lake County.